PIM Series 3 Interface Module
$0.00Price
The Presco Interface Module (PIM) is used to convert commonly used data formats into the required data format to suit the target device.
FEATURES
12 Volt D.C. operation.
36 month manufacturer’s warranty.
23 possible conversions:
Presco™ to:
● RS-232 ● Wiegand ● Clock & Data
Wiegand to:
● Presco™ ● RS-232 ● Wiegand
● Clock & Data ● Presco™ (PDA / KC series)
Clock & Data to:
● Presco™ ● RS-232 ● Wiegand
● Clock & Data ● Presco™ (PDA / KC series)
Dallas iButton™ to:
● Presco™ ● RS-232 ● Wiegand
● Clock & Data ● Presco™ (PDA / KC series)
RS-232 to:
● Presco™ ● Wiegand ● Clock & Data
● Presco™ (DLOG)
Presco™ (DLOG) to:
● RS-232
Supports wiegand formats up to 64 bit with site codes up to 32 bits.
Reads up to 64 bits from Dallas I button™ user memory or 56 bits from factory ID.
Reads up to 32 characters or digits from Track 1, 2 or 3 from Clock & Data (magnetic card) format input.
Details
Operating Voltage: 10 - 15 Volts D.C.
Operating Current: 30 mA. @ 12 Volts D.C.
Wiegand Output: Pulse width = 50μs, Pulse separation = 2ms
RS-232 Baud Rate:300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600 or 115200 bps
RS-232 Data bits: 8
RS-232 Parity: None, Odd or Even
RS-232 Handshaking: Hardware or None