PIM Series 3 Interface Module

PIM Series 3 Interface Module

The Presco Interface Module (PIM) is used to convert commonly used data formats into the required data format to suit the target device.

FEATURES
12 Volt D.C. operation.
36 month manufacturer’s warranty.
23 possible conversions:
Presco™ to:
● RS-232 ● Wiegand ● Clock & Data

Wiegand to:
● Presco™ ● RS-232 ● Wiegand
● Clock & Data ● Presco™ (PDA / KC series)

Clock & Data to:
● Presco™ ● RS-232 ● Wiegand
● Clock & Data ● Presco™ (PDA / KC series)

Dallas iButton™ to:
● Presco™ ● RS-232 ● Wiegand
● Clock & Data ● Presco™ (PDA / KC series)

RS-232 to:
● Presco™ ● Wiegand ● Clock & Data
● Presco™ (DLOG)

Presco™ (DLOG) to:
● RS-232

Supports wiegand formats up to 64 bit with site codes up to 32 bits.
Reads up to 64 bits from Dallas I button™ user memory or 56 bits from factory ID.
Reads up to 32 characters or digits from Track 1, 2 or 3 from Clock & Data (magnetic card) format input.
  • Details

    Operating Voltage: 10 - 15 Volts D.C.
    Operating Current: 30 mA. @ 12 Volts D.C.
    Wiegand Output: Pulse width = 50μs, Pulse separation = 2ms
    RS-232 Baud Rate:300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600 or 115200 bps
    RS-232 Data bits: 8
    RS-232 Parity: None, Odd or Even
    RS-232 Handshaking: Hardware or None